Defense subcontractors can isolate CUI in an enclave for about $15,000 instead of rebuilding the network for CMMC Level 2.
How a small defense subcontractor can isolate Controlled Unclassified Information in an enclave and prepare for CMMC Level 2 without rebuilding its whole network.
The Drawing on the Shop Floor
Picture a hypothetical precision machine shop—call it “Alpine CNC”—that has been cutting titanium parts for a Tier 1 defense prime since 2018. The work comes in as a set of ITAR-controlled CAD files and engineering drawings stamped CUI//SP-EXPT. For years those drawings lived on a shared Windows folder, accessible by anyone on the company Wi-Fi, backed up to a USB drive the owner kept in their truck. Nobody from the prime ever audited the arrangement. That era is over.
On November 10, 2025, the Department of Defense began putting CMMC requirements into new contracts. Over the next few years, Alpine CNC and shops like it will need to show that they meet the 110 security requirements of NIST SP 800-171 Revision 2, the version CMMC Level 2 is built on, and in many cases have that verified by an independent assessor. The good news: you do not have to rearchitect your entire network or write a six-figure check to a Beltway consulting firm. For a small shop, a CUI enclave can be built for roughly fifteen thousand dollars, including outside help, plus a few weekends of focused work.
Which Version of SP 800-171 Applies
SP 800-171 is the security standard for non-federal organizations that handle Controlled Unclassified Information (CUI) for the federal government, and DFARS clause 252.204-7012 has required defense contractors to meet it since 2017. Two versions matter right now.
- Revision 2 (2020) has 110 requirements in 14 families, numbered 3.1.1 through 3.14.7. The CMMC program rule (32 CFR Part 170, effective December 16, 2024) builds Level 2 on Rev. 2, and a DoD class deviation issued in May 2024 keeps Rev. 2 as the version contractors are held to under DFARS 252.204-7012 for now. Assessors use the matching assessment guide, SP 800-171A (2018), and its 320 assessment objectives.
- Revision 3 (May 2024) has 97 requirements in 17 families. It aligns the wording with NIST SP 800-53 Rev. 5, adds Planning, System and Services Acquisition, and Supply Chain Risk Management families, and introduces organization-defined parameters, so you must state values such as session timeouts yourself. NIST’s assessment guide, SP 800-171A Rev. 3, lists determination statements for each requirement.
Key takeaway: build and document to Rev. 2’s 110 requirements, because that is what a CMMC Level 2 assessment checks today, and keep an eye on Rev. 3, which DoD is expected to adopt later. Rev. 3 removes ambiguity more than it adds obligations, so a well-built enclave carries over.
For a small shop, the families that tend to cause the most pain are Audit and Accountability, System and Communications Protection, and Configuration Management, because they require working technical controls, not just policy documents.
The Enclave Strategy: Shrink the Boundary
Here is the single most important concept for any sub with fewer than fifty employees: you do not have to make your entire network 800-171 compliant. You need to make the systems that process, store, or transmit CUI compliant. Everything else just needs to be separated from those systems with a defensible boundary.
This is the CUI enclave approach. Think of it as building a clean room inside your existing facility. The CNC machines, the accounting PC running QuickBooks, the break room Roku—none of that needs to meet the 110 requirements. You carve out a subnet, put the machines that touch CUI drawings on it, wrap it in firewall rules and access controls, and focus all of your compliance energy on that enclave. The rest of your network becomes “out of scope,” provided you can demonstrate the boundary is enforced.
For the hypothetical Alpine CNC, the enclave is three workstations in the engineering office, one file server, and the link between those machines and the prime’s secure file transfer portal. That is it. The shop floor PLCs, the front desk laptop, the owner’s phone—all outside the boundary. This dramatically reduces the cost and complexity of compliance.
Architecture on a $15,000 Budget
Let me walk through the actual architecture, component by component, with real products and approximate street prices as of late 2025. Prices change, so treat them as a guide.
Network Segmentation
The enclave starts at the network layer. You need a firewall or router that can enforce a dedicated VLAN for CUI systems and block all traffic between the CUI VLAN and the corporate/guest VLANs except for explicitly allowed flows. A pfSense or OPNsense appliance running on a Protectli Vault (the FW4B or FW6B model) gives you enterprise-grade stateful firewalling, VLAN trunking, and VPN termination for around $400. Pair it with a managed switch—a Ubiquiti USW-24-PoE or a TP-Link TL-SG3428 will do—that supports 802.1Q VLAN tagging. Budget another $300 for the switch. Total network segmentation cost: roughly $700.
Configure VLAN 100 as your CUI enclave. Assign it a distinct subnet—say 10.171.100.0/24. Set your firewall rules to deny all traffic from any other VLAN into VLAN 100 except for the specific ports required for DNS, NTP, Windows Update, and your SIEM collector. Document the ruleset. That documentation becomes evidence for 3.13.1 (monitor and control communications at the boundary) and 3.13.6 (deny network traffic by default).
Multi-Factor Authentication
Every account that can reach the CUI enclave needs MFA. For a three-workstation environment, the simplest path is Duo Security’s free tier (up to 10 users) or, if you want more control, a set of YubiKey 5 NFC tokens at about $50 each. For three engineers and one admin, that is $200 in hardware. Duo Authentication for Windows Logon and RDP adds MFA at the desktop and for RDP sessions. This covers 3.5.3 (multifactor authentication for privileged accounts and for network access to non-privileged accounts).
Encrypted File Storage
The CUI drawings need to be stored on an encrypted share with access limited to authorized personnel. A Synology DS423+ NAS (around $550) running in the CUI VLAN with volume-level encryption enabled (AES-256) and Active Directory-joined for access control gives you a proper file server. Enable SMB signing, disable SMB1, turn on the Synology audit log, and restrict share permissions to the specific AD group you create for CUI-authorized users. That NAS also gives you versioning and snapshot-based backups to an encrypted USB volume or a second NAS. This supports 3.13.16 (protect CUI at rest), 3.8.9 (protect backups of CUI) and 3.1.2 (limit access to authorized transactions and functions).
One caution: when encryption is what protects CUI, 3.13.11 requires FIPS-validated cryptography. Check NIST’s Cryptographic Module Validation Program list for the NAS’s encryption module before you rely on it. Many small-business NAS products are not on that list. If yours is not, a Windows file server with BitLocker in FIPS mode is a common alternative.
Endpoint Protection
The three enclave workstations and the NAS need endpoint detection and response (EDR) that actually logs telemetry, not just consumer antivirus. Small-business options include CrowdStrike Falcon Go and Microsoft Defender for Business, both licensed per device or per user per year; the bill of materials below allows $400 for the first year. Either way, you need centralized logging of process execution, file access, and network connections. This addresses 3.14.2 (malicious code protection), 3.14.6 (monitor systems for attacks) and 3.3.1 (create and retain audit logs).
SIEM-Lite: Wazuh
You need a place to collect, correlate, and retain security logs. For a small enclave, Wazuh is hard to beat. It is open source, it runs on a modest Linux VM, and it provides file integrity monitoring, log aggregation, vulnerability detection, and compliance dashboards out of the box. Stand up an Ubuntu 24.04 LTS VM on a repurposed desktop or a $300 mini PC (a Beelink SER5 with 16 GB of RAM handles it comfortably), install the Wazuh all-in-one deployment, and point your enclave workstations and NAS at it via the Wazuh agent. Total cost: the hardware. Rev. 2 does not set a retention period, so choose one, such as one year, write it in your SSP and configure it; that supports 3.3.1. Wazuh tags its rules with NIST SP 800-53 controls, the catalog 800-171 is drawn from, which helps when you sit down to write your SSP.
Secure Remote Access
If any of your engineers need to reach the CUI enclave from outside the building—say, from a home office or a client site—you need a VPN that terminates inside the enclave boundary. The pfSense/OPNsense box you already bought can run WireGuard or OpenVPN. Combine it with the MFA tokens you already bought. Total additional cost: zero. Just configuration and documentation. This addresses 3.1.12 (monitor and control remote access) and 3.1.13 (protect remote sessions with cryptography). The FIPS caution above applies here too.
Backup and Recovery
SP 800-171 Rev. 2 has no backup requirement of its own, but it requires backups of CUI to be protected (3.8.9), and you will want to recover after ransomware. The Synology NAS supports Hyper Backup to an encrypted external USB drive. Buy a pair of 4 TB IronWolf drives ($120 each) and a USB 3.0 dock ($40). Rotate the drives weekly and store the off-site copy in a locked safe or a bank safe deposit box in town. Test a restore every quarter and record it. Total: $280.
Bill of Materials
| Component | Product | Purpose | Approx. Cost |
|---|---|---|---|
| Firewall/Router | Protectli Vault FW4B + OPNsense | VLAN enforcement, VPN, boundary protection | $400 |
| Managed Switch | Ubiquiti USW-24-PoE or TP-Link TL-SG3428 | 802.1Q VLAN trunking for enclave segmentation | $300 |
| MFA Tokens | YubiKey 5 NFC (x4) | Phishing-resistant multi-factor authentication | $200 |
| Encrypted NAS | Synology DS423+ (2x 4 TB drives, RAID 1) | CUI file storage, encrypted at rest, audit logging | $900 |
| SIEM Server | Beelink SER5 Mini PC (16 GB RAM) + Wazuh | Log aggregation, FIM, compliance dashboards | $300 |
| EDR Licensing | CrowdStrike Falcon Go or Microsoft Defender for Business (4 endpoints, Year 1) | Endpoint detection, telemetry, malware protection | $400 |
| Backup Hardware | 2x Seagate IronWolf 4 TB + USB 3.0 Dock | Encrypted offline backups with rotation | $280 |
| Cabling & Misc. | Cat6 patch cables, rack shelf, labels | Physical installation | $120 |
| Total Estimated Hardware & Year-1 Licensing | $2,900 | ||
That hardware total leaves substantial headroom in a $15,000 budget. The remaining roughly $12,000 covers the labor-intensive part: writing the System Security Plan, conducting a risk assessment, developing your incident response plan, training your staff, and—if you want a second set of eyes—engaging a consultant for a pre-assessment readiness review. For a three-to-five person enclave, an experienced CMMC Registered Practitioner can often do a gap assessment and SSP review in 20 to 30 hours. The rest goes toward your time, your IT person’s time, and the inevitable surprises (a Windows license upgrade here, a domain controller tweak there).
The Evidence Pack: What Your Assessor Wants to See
Building the enclave is half the job. The other half is proving it works. A CMMC Level 2 assessor is going to ask for artifacts that map to each of the 110 requirements and their assessment objectives. Here is a starter list of the documents and technical evidence you should prepare alongside the build.
| Artifact | Covers Requirements | What to Include |
|---|---|---|
| System Security Plan (SSP) | 3.12.4, and all 110 (narrative for each) | System boundary description, enclave network diagram, data flow diagram, per-requirement implementation narrative addressing each assessment objective, POA&M for any gaps |
| Network Diagram | 3.13.1, 3.1.3, 3.13.6 | Enclave VLAN topology, firewall rule summary, data flow arrows showing CUI ingress/egress paths, clear boundary marking between CUI and non-CUI zones |
| Access Control Matrix | 3.1.1, 3.1.2, 3.1.5, 3.5.3 | Table of users, roles, CUI share permissions, MFA enrollment status, principle-of-least-privilege justification for each account |
| Audit Log Samples | 3.3.1, 3.3.2, 3.3.5 | Wazuh dashboard screenshots, sample syslog entries showing logon events, file access events, and failed authentication attempts; evidence of the retention period you configured |
| Incident Response Plan | 3.6.1, 3.6.2, 3.6.3 | Roles and responsibilities, escalation procedures, DoD reporting under DFARS 252.204-7012 (within 72 hours of discovery), tabletop exercise records |
| Configuration Baselines | 3.4.1, 3.4.2, 3.4.6, 3.4.8 | CIS Benchmark output for enclave workstations, GPO export, disabled services list, software allow list |
| Risk Assessment Report | 3.11.1, 3.11.2, 3.11.3 | Vulnerability scan results (Wazuh or Nessus Essentials), risk register with likelihood/impact ratings, remediation plan for identified findings |
| Training Records | 3.2.1, 3.2.2 | Sign-off sheets for annual CUI handling and cybersecurity awareness training, training content outline, dates and attendees |
| Media Protection Log | 3.8.1, 3.8.3, 3.8.9 | Encrypted backup rotation log, sanitization records for decommissioned drives, physical media inventory |
Practical tip: Build your SSP as a living document from day one. Every time you configure a firewall rule, enroll a YubiKey, or run a vulnerability scan, write a two-sentence note in the relevant SSP section and save the screenshot. Trying to reconstruct six months of work the week before an assessment is miserable and error-prone.
How This Connects to CMMC Level 2
CMMC Level 2 is the 110 requirements of SP 800-171 Rev. 2, assessed against the 320 objectives in SP 800-171A. If you build an enclave that meets every requirement and you can produce the evidence pack described above, you are ready for a CMMC Level 2 assessment by a Certified Third-Party Assessor Organization (C3PAO). The assessment itself involves a review of your SSP, examination of your artifacts, interviews with your staff, and testing of your technical controls.
For contracts that call for a Level 2 self-assessment, you post your score in the Supplier Performance Risk System (SPRS) and a senior official affirms it every year. A perfect score is 110, and each requirement not met costs one, three or five points. A Plan of Action and Milestones (POA&M) does not add points back. Under CMMC you can receive a conditional status with a score of at least 88 if only certain lower-weighted requirements are on the POA&M, and you then have 180 days to close them. The enclave approach, done properly, should get a small shop to a full 110 without heroics.
For contracts that require a C3PAO assessment, the enclave boundary becomes your best friend during the evaluation. The assessor only needs to examine the systems inside the boundary and the controls that enforce it. A three-workstation enclave makes for a much shorter assessment than a whole-company network. It saves you money, reduces disruption to your shop floor, and keeps the assessor focused on a well-documented, well-controlled environment instead of wandering through an unmanaged flat network asking uncomfortable questions.
Getting Started This Quarter
If you are a machine shop, engineering firm, or defense subcontractor reading this in late 2025, here is the sequence I would follow. First, identify exactly which data in your environment qualifies as CUI—check your contract for DFARS 252.204-7012 and the newer CMMC clause, 252.204-7021, and the markings on any drawings or technical data packages you receive. Second, identify the minimum set of machines that need to touch that data. Third, order the hardware in the bill of materials above and spend a weekend building the enclave VLAN. Fourth, install Wazuh and your EDR, configure your encrypted NAS, and enroll your users in MFA. Fifth, start writing the SSP, one requirement family at a time, while the configuration is fresh in your mind. Sixth, run a vulnerability scan, fix what it finds, and save the before-and-after reports. Seventh, train your CUI-handling personnel and document it. If the drawings are ITAR-controlled, also confirm that only U.S. persons can reach them, which is an export-control rule separate from 800-171.
None of this requires a massive IT department. It requires a methodical approach, a free weekend or two, and the willingness to treat cybersecurity as part of your manufacturing process—the same way you treat calibration records or material certifications. You already know how to maintain quality systems. This is just a quality system for information.
If you would like a second set of eyes on where your CUI lives and what your enclave should include, Security Medic Consulting offers a free 30-minute call. You own the enclave and the SSP; we can help you scope it, review the evidence, and get ready for the assessor.
References
- NIST, SP 800-171 Rev. 2, Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations. https://csrc.nist.gov/pubs/sp/800/171/r2/upd1/final
- NIST, SP 800-171 Rev. 3, May 2024. https://csrc.nist.gov/pubs/sp/800/171/r3/final
- Department of Defense, Cybersecurity Maturity Model Certification (CMMC) Program, 32 CFR Part 170. https://www.ecfr.gov/current/title-32/subtitle-A/chapter-I/subchapter-G/part-170
- DoD CIO, CMMC resources and documentation. https://dodcio.defense.gov/CMMC/
- NIST, Cryptographic Module Validation Program. https://csrc.nist.gov/projects/cryptographic-module-validation-program